Comparison nJoy Horus Plus 1000 1000 VA vs PowerWalker Basic VI 1000 STL 1000 VA

Add to comparison
nJoy Horus Plus 1000 1000 VA
PowerWalker Basic VI 1000 STL 1000 VA
nJoy Horus Plus 1000 1000 VAPowerWalker Basic VI 1000 STL 1000 VA
Compare prices 26Compare prices 6
TOP sellers
Main
Interactive UPS. Cold start.
Typesmartsmart
Form factorstandard (Tower)standard (Tower)
Half load operating time5.5 min5.5 min
Switching to battery6 ms4 ms
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range170 – 280 V162 – 290 V
Input frequency50/60 Hz50/60 Hz
Bypass (direct connection)is absentis absent
Output
Output voltage1 phase (230V)1 phase (230V)
Max. output power1000 VA1000 VA
Rated output power600 W600 W
Efficiency96 %
Output waveformsimilar to a sinusoid (approximated)similar to a sinusoid (approximated)
Output frequency50/60 Hz50/60 Hz
Redundant sockets42
Socket typetype F (Schuko)type F (Schuko)
Battery
Battery typelead acid
Supplied battery(s) capacity7 Ah9 Ah
Batteries21
Full charge time360 min480 min
Cold start
Protection
Protection
short circuit protection
overload protection
noise filtering
data line protection
sound alarm
short circuit protection
overload protection
noise filtering
data line protection
sound alarm
Fuseautomelting
Control interfaces
USB
USB
General
Screen
Operating temperature0 – 40 °C0 – 40 °C
Noise level40 dB
Dimensions (HxWxD)182x130x320 mm138x96x286 mm
Weight7.8 kg4.9 kg
Added to E-Catalogseptember 2020june 2018

Switching to battery

The time required to transfer the load from mains power to battery power. In standby and interactive UPSs (see Type), a short-term power failure occurs at this moment — accordingly, the shorter the time to switch to the battery, the more uniform the power supply is provided by the source during a power failure. Ideally, the switching time for the traditional 50 Hz AC frequency should be less than 5 ms (a quarter of one cycle of the sine wave). With inverter UPSs, the transfer time is, by definition, zero.

Input voltage range

In this case, the input voltage range is implied, in which the UPS is able to supply a stable voltage to the load only due to its own regulators, without switching to the battery. For redundant UPSs (see "Type") this range is quite small, approximately 190 to 260 V; for interactive and especially inverter ones, it is much wider. Some UPS models allow you to manually set the input voltage range.

Efficiency

Efficiency (coefficient of performance) in the case of a UPS is the ratio of its output power to the power consumed from the network. This is one of the main parameters that determine the overall efficiency of the device: the higher the efficiency, the less energy the UPS wastes (due to heating parts, electromagnetic radiation, etc.). In modern models, the efficiency value can reach 99%.

Redundant sockets

The number of outlets connected to the power reserve(battery) provided in the design of the UPS. In order for the UPS to fulfill its main role (providing a backup power in case of power outages), the corresponding electrical appliances must be connected to these outlets. The sockets have a standard shape and are compatible with the vast majority of popular 230 V plugs.

At a minimum, the UPS has 1 or 2 outlets and, in more advanced ones, there may be 3 or more.

Battery type

- Lead acid. Structurally, lead-acid batteries are based on a combination of electrodes made of lead compounds immersed in a liquid electrolyte, the role of which is played by an aqueous solution of sulfuric acid. The advantages of this type are simplicity and low cost, low self-discharge, no "memory effect" and maintaining performance in a wide temperature range. At the same time, the less charge remains in such batteries, the less current they produce. Also, lead-acid batteries are afraid of deep discharges, take a long time to charge, have large dimensions and weight in the context of other types.

- Lead-acid (AGM). An advanced type of lead-acid battery with an electrolyte in a jelly-like state. The gel electrolyte provides maximum contact with the negative and positive plates while maintaining a uniform consistency throughout the volume. AGM batteries impress with their high reliability, low self-discharge, deep discharge resistance and long service life. However, they are sensitive to charge quality, short circuits and negative temperatures.

— Li-Ion. Lithium-ion batteries have a high capacity with small dimensions and weight. They are not subject to the “memory effect”, they are able to charge quite quickly, they can boast of an excellent reserve for charge-discharge cycles. Li-Ion batteries also have disadvantages - first of all, it is sensitivity to low or high temperatures, and when overloaded, such a battery can catch fire or even explode. Howeve...r, due to the use of embedded controllers, the likelihood of such "accidents" is extremely small and, in general, the advantages of this technology significantly outweigh the disadvantages.

Supplied battery(s) capacity

The capacity of the battery installed in the UPS. For models with multiple batteries, this is both the total working capacity and the capacity of each individual battery: the batteries in such devices are usually connected in series, so that their total capacity corresponds to the capacity of each individual cell.

Theoretically, a higher battery capacity means the ability to power loads of a given capacity for longer. However, in fact, this parameter is more of a reference than practically significant. The fact is that the actual amount of energy stored by the battery depends not only on the capacity in amp-hours, but also on the voltage in volts; this voltage is often not specified in the characteristics, despite the fact that for accurate calculations it must be known. So when choosing, you should focus on more "close to life" characteristics — first of all, on the directly claimed operating time in different modes (see above).

Batteries

The number of batteries supplied with the UPS.

In general, this parameter is more of a reference than practically significant: the number of batteries is selected in such a way as to provide the desired performance — primarily the time of continuous operation. First of all, it is worth paying attention to such characteristics when choosing.

Full charge time

The time it takes to fully charge the UPS battery. Note that in this case, this time is calculated according to special rules: not from 0 to 100% of the charge, but from a state in which it is impossible to maintain half the load, up to 90% of the charge. Of course, a full charge will take a little longer. However, this data is closer to practice than the “from 0 to 100%” calculation: the inability to work at half load makes the UPS practically useless, and this condition can be taken as zero, and 90% of the battery is already able to provide a good guarantee in case of a power failure.

Fuse

Fuses are used to protect the UPS from a critical increase in current strength: at the right time, they open the circuit, preventing unpleasant consequences. Today, these types of fuses are used.

— Melting. At a critical current strength, the conductive element in such a fuse melts and opens the circuit. The fusible protection is disposable, after operation such a fuse must be replaced.

— Automatic. Such a fuse has a sensor that monitors the current strength and opens the contacts at the right time. Its main difference from fusible is reusability: after operation, the circuit can be closed again with literally one press of the button on the fuse.